From 159bcfa17362ae0d0a9ed2a172d5df6c747a21f9 Mon Sep 17 00:00:00 2001 From: "Peter F. Patel-Schneider" Date: Fri, 15 Jul 2022 11:53:56 -0400 Subject: [PATCH] device: use correct Solaar functions for unified and voltage battery functions --- lib/logitech_receiver/hidpp20.py | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/lib/logitech_receiver/hidpp20.py b/lib/logitech_receiver/hidpp20.py index a60471fe..dbb2141e 100644 --- a/lib/logitech_receiver/hidpp20.py +++ b/lib/logitech_receiver/hidpp20.py @@ -1333,8 +1333,8 @@ def decipher_adc_measurement(report): battery_functions = { FEATURE.BATTERY_STATUS: get_battery_status, - FEATURE.BATTERY_VOLTAGE: get_battery_unified, - FEATURE.UNIFIED_BATTERY: get_battery_voltage, + FEATURE.BATTERY_VOLTAGE: get_battery_voltage, + FEATURE.UNIFIED_BATTERY: get_battery_unified, FEATURE.ADC_MEASUREMENT: get_adc_measurement, }