fixed wrong interpretation of bit 6 of the notification byte which indicates if the link could be established (bit cleared) or not (bit set)

https://lekensteyn.nl/files/logitech/logitech_hidpp10_specification_for_Unifying_Receivers.pdf
This commit is contained in:
vbs 2016-09-16 19:05:47 +02:00 committed by verybadsoldier
parent fa5fba796b
commit 358e0958bb
1 changed files with 1 additions and 1 deletions

View File

@ -80,7 +80,7 @@ class PairedDevice(object):
# _log.debug("new PairedDevice(%s, %s, %s)", receiver, number, link_notification)
if link_notification is not None:
self.online = bool(ord(link_notification.data[0:1]) & 0x40)
self.online = not bool(ord(link_notification.data[0:1]) & 0x40)
self.wpid = _strhex(link_notification.data[2:3] + link_notification.data[1:2])
# assert link_notification.address == (0x04 if unifying else 0x03)
kind = ord(link_notification.data[0:1]) & 0x0F