fix: hermes update restarts gateway via PID file (HERMES_HOME-scoped)

Root cause of duplicate gateways: hermes update only restarted
the systemd service, leaving manually-started gateway processes
alive. The two ran simultaneously on different PIDs.

Fix: cmd_update now uses get_running_pid() from gateway.status
which reads the PID file scoped to HERMES_HOME. This kills only
the gateway for THIS installation — safe with multiple Hermes
installations on the same machine. Then restarts the systemd
service if active.

The PID file approach (vs ps aux pattern matching) ensures we
never accidentally kill a gateway from a different installation.
This commit is contained in:
teknium1 2026-03-12 19:36:36 -07:00
parent 319e6615c3
commit 6873c9f7db
1 changed files with 50 additions and 18 deletions

View File

@ -1881,26 +1881,58 @@ def cmd_update(args):
print()
print("✓ Update complete!")
# Auto-restart gateway if it's running as a systemd service
# Auto-restart gateway if it's running.
# Uses the PID file (scoped to HERMES_HOME) to find this
# installation's gateway — safe with multiple installations.
try:
check = subprocess.run(
["systemctl", "--user", "is-active", "hermes-gateway"],
capture_output=True, text=True, timeout=5,
)
if check.stdout.strip() == "active":
print()
print("→ Gateway service is running — restarting to pick up changes...")
restart = subprocess.run(
["systemctl", "--user", "restart", "hermes-gateway"],
capture_output=True, text=True, timeout=15,
from gateway.status import get_running_pid, remove_pid_file
import signal as _signal
existing_pid = get_running_pid()
has_systemd_service = False
try:
check = subprocess.run(
["systemctl", "--user", "is-active", "hermes-gateway"],
capture_output=True, text=True, timeout=5,
)
if restart.returncode == 0:
print("✓ Gateway restarted.")
else:
print(f"⚠ Gateway restart failed: {restart.stderr.strip()}")
print(" Try manually: hermes gateway restart")
except (FileNotFoundError, subprocess.TimeoutExpired):
pass # No systemd (macOS, WSL1, etc.) — skip silently
has_systemd_service = check.stdout.strip() == "active"
except (FileNotFoundError, subprocess.TimeoutExpired):
pass
if existing_pid or has_systemd_service:
print()
# Kill the PID-file-tracked process (may be manual or systemd)
if existing_pid:
try:
os.kill(existing_pid, _signal.SIGTERM)
print(f"→ Stopped gateway process (PID {existing_pid})")
except ProcessLookupError:
pass # Already gone
except PermissionError:
print(f"⚠ Permission denied killing gateway PID {existing_pid}")
remove_pid_file()
# Restart the systemd service (starts a fresh process)
if has_systemd_service:
import time as _time
_time.sleep(1) # Brief pause for port/socket release
print("→ Restarting gateway service...")
restart = subprocess.run(
["systemctl", "--user", "restart", "hermes-gateway"],
capture_output=True, text=True, timeout=15,
)
if restart.returncode == 0:
print("✓ Gateway restarted.")
else:
print(f"⚠ Gateway restart failed: {restart.stderr.strip()}")
print(" Try manually: hermes gateway restart")
elif existing_pid:
print(" Gateway was running manually (not as a service).")
print(" Restart it with: hermes gateway run")
except Exception as e:
logger.debug("Gateway restart during update failed: %s", e)
print()