Commit Graph

9 Commits

Author SHA1 Message Date
ethernet 25d0bcd424 fix(runtime): resolve Hermes-managed Node and uv before bare PATH
Hermes installs runtimes for itself — `uv` at `$HERMES_HOME/bin/uv`, Node
at `$HERMES_HOME/node` — and neither directory is on an arbitrary
process's PATH. Every `shutil.which("node"/"npm"/"npx"/"uv")` in Hermes's
own code therefore has two failure modes: the managed runtime is invisible,
so the caller reports "not installed" or degrades to a slower tier on a
machine that has exactly what it needed; and when a system copy also
exists, the one Hermes does not own wins.

Routed the Hermes-owned call sites through managed-aware resolvers:

- `agent/lsp/install.py`, `hermes_cli/dep_ensure.py`, `hermes_cli/main.py`
  (`_make_tui_argv`), `hermes_cli/tools_config.py` (`_run_post_setup`) now
  use `find_node_executable()`.
- `hermes_cli/tools_config.py::_pip_install` and `hermes_cli/setup.py`'s
  vercel install use `ensure_uv()` (installing uv is in scope during setup,
  and the Windows installer's `uv venv` does not seed pip, so the fallback
  tier is "No module named pip"). `tools/lazy_deps.py` uses `resolve_uv()`
  — a lookup, not a bootstrap, because it runs mid-turn for an optional
  dependency and downloading a runtime as a side effect exceeds what the
  caller asked for.
- `hermes_cli/gateway.py`: extracted `_append_node_dir_for_service()`,
  shared by the systemd unit and launchd plist generators, which appends
  the managed dirs before the PATH-resolved one. A service definition is
  written once and survives reboots, so resolving a system Node that
  happens to lead the installing shell's PATH bakes the wrong interpreter
  in permanently. Managed dirs are profile-scoped, so each profile's unit
  still names its own Node; the existing symlink-parent rule (don't
  `.resolve()`) is preserved verbatim.
- `tools/environments/local.py`: the terminal tool's subshell PATH gains
  the managed dirs, appended alongside the sane entries rather than
  prepended — a tool the user deliberately put on their own PATH still
  wins, and the managed one only fills a gap. This is also what makes the
  bare `which("uv")` in `tools/env_probe.py` correct: that probe reports
  the environment the *model* sees, and the model can only run what is on
  that subshell's PATH.

`scripts/install.ps1`: the persisted User PATH update becomes
`Set-ManagedNodeFirstOnUserPath`, a move-to-front rather than an
add-if-missing. Installs made by an older install.ps1 already have the
managed dir in User PATH — at the tail, behind a system Node — and an
add-if-missing check sees it present and leaves that ordering in place
forever, so the users the bug hurt would never be repaired. Unrelated
entries keep their relative order (empty segments included; a trailing
`;` is legal and the installer's other PATH code preserves them),
duplicates collapse, and it writes only when the string actually changes.

Tests:

- `tests/test_managed_runtime_resolution.py` — AST guard that fails any
  new bare `which()` for a managed runtime, with a short justified
  allow-list and a companion test that fails when an allow-list entry goes
  stale. Reading source is banned by AGENTS.md and this is the documented
  exception: the property is "no call site anywhere spells it this way",
  which no runtime seam can observe.
- `scripts/ci/test_install_ps1_path_migration.ps1` — behavioral, not a
  source regex: it lifts the real `Set-ManagedNodeFirstOnUserPath` out of
  install.ps1's AST and rewrites only the two registry calls into an
  in-memory store, so the shipped split/dedupe/prepend/change-detection
  logic executes for real. Not in the default lane (Linux runners have no
  PowerShell host); runs under `pwsh`. 13/13 assertions pass.
2026-08-01 21:17:51 -04:00
Teknium c770515e2b modernize re-added Vercel integrations: SDK 0.7.2, telemetry off, sibling-site wiring
- Bump vercel SDK pin 0.5.7 -> 0.7.2 (pyproject, lazy_deps) and regenerate uv.lock
- Disable the SDK's new default-on telemetry (VERCEL_TELEMETRY_DISABLED=1
  set before import, user-overridable) per the no-opt-out-telemetry policy
- Move _model_flow_ai_gateway into hermes_cli/model_setup_flows.py (god-file
  decomposition landed after the removal)
- Widen post-removal backend sets that vercel_sandbox missed: terminal_tool
  container_backend + _CONTAINER_BACKENDS, file_tools fallback set,
  env_probe._REMOTE_BACKENDS, approval._should_skip_container_guards,
  prompt_builder probe container_config
- Add terminal.vercel_runtime to config_defaults + TERMINAL_CONFIG_ENV_MAP
- Re-add vercel dependency group to nix #full variant (reverts #33773 workaround)
- Update restored tests to current contracts: upload-only credential sync-back
  (bcfc7458fa), registry-derived provider env list, parametrized backend fixture,
  drop tests superseded on main (slack wizard move #41112, nous status format)
2026-07-29 19:48:37 -07:00
teknium1 5b751dc0ad chore: remove unused imports and dead locals (ruff F401/F841 sweep)
Cleans F401 unused imports and F841 dead local assignments across
root *.py, agent/, hermes_cli/, tools/, gateway/, cron/, tui_gateway/
(tests/, plugins/, skills/ excluded).

Intentionally KEPT (false positives / test-patch surfaces):
- agent/transports/__init__.py package re-exports
- cli.py browser_connect re-exports (DEFAULT_BROWSER_CDP_URL area,
  used by tests/cli/test_cli_browser_connect.py)
- hermes_cli/main.py _prompt_auth_credentials_choice /
  _model_flow_bedrock_api_key (accessed via main_mod attr in tests)
- gateway/run.py aliased replay_cleanup + whatsapp_identity re-exports
  and _PORT_BINDING_PLATFORM_VALUES (test-referenced)
- hermes_cli/web_server.py get_running_pid (tests monkeypatch it) and
  _OAUTH_TOKEN_URL availability probe
- hermes_cli/config.py get_process_hermes_home re-export (noqa'd F811
  chain) and yaml availability-probe import
- hermes_cli/nous_subscription.py managed_nous_tools_enabled
  (tests patch hermes_cli.nous_subscription.managed_nous_tools_enabled)
- try/except ImportError availability probes (env_loader, tts_tool,
  mcp_tool, web_server anthropic OAuth block)
- tools/web_tools.py noqa F401 re-exports
- hermes_cli/setup_whatsapp_cloud.py:263 'proceed' skipped: possible
  missing-guard bug, flagged for separate review
- unused function parameters (signature changes out of scope)

Side-effect RHS calls preserved where only the binding was dead
(e.g. web_server proc = _spawn_hermes_action -> bare call).
2026-07-29 11:53:39 -07:00
Teknium 0b17d4d71e fix(windows): re-fit env_probe console suppression to the temp-file _run + add no-window tests (#67690 follow-up)
Follow-up to the #67690 salvage (@m4r13y). The PR's tools/env_probe.py
hunk was written against the old capture_output=True _run(); #67964/#67999
rewrote _run to temp-file capture on July 20, so that hunk no longer
applied — but the rewritten _run still lacked creationflags and kept
flashing one console per probe (~5 per kanban worker start) from
windowless parents. Re-implement the one-line fix against the current
shape: creationflags=windows_hide_flags() on the temp-file subprocess.run,
preserving the #67964 grandchild-can't-wedge-the-pipe contract.

Also add the tests the PR didn't ship, in
tests/test_windows_subprocess_no_window_flags.py:
- env_probe._run passes CREATE_NO_WINDOW and keeps temp-file (non-PIPE)
  stdout/stderr + DEVNULL stdin
- lazy_deps uv install / pip --version probe / pip install fallback /
  ensurepip bootstrap all pass CREATE_NO_WINDOW
- suppress_platform_ver_console: POSIX no-op (platform._syscmd_ver
  untouched, win32_ver() still returns), and simulated-Windows stubbing
  (echo stub installed, idempotent, never raises)
2026-07-23 18:20:24 -07:00
PRATHAMESH75 e77ffdc28c fix(tools): bound env probe subprocess so a Windows inherited pipe can't wedge sessions (#67964) 2026-07-20 06:50:11 -07:00
Teknium b9dba7eff5
fix(env-probe): stuck Windows probe can no longer deadlock system-prompt builds (#67999)
An orphaned pip descendant holding the probe's inherited stdout/stderr
pipe handles wedged subprocess.run's post-timeout communicate() (which
joins the pipe reader threads with NO timeout on Windows). The warm
probe thread then hung holding the module-level _CACHE_LOCK, so every
new session's prompt build blocked indefinitely (#67964).

Two layers:

- _run(): replace subprocess.run with Popen + communicate(timeout); on
  TimeoutExpired kill the process TREE (taskkill /T on Windows) and
  reap the direct child bounded — never re-read the pipes, so an
  orphaned descendant holding them open can't block us.
- get_environment_probe_line(): the probe now runs in a single
  background worker publishing via a threading.Event; callers wait at
  most _PROBE_WAIT_TIMEOUT (10s) then fail open with "". After one
  full timeout, later callers only peek. If the stuck worker ever
  finishes, its line resumes appearing in new prompts.

Regression tests: hung probe with 4 concurrent callers returns bounded;
late recovery publishes; repeat callers skip the wait; _run() returns
promptly despite a pipe-holding descendant (real subprocess E2E).

Fixes #67964
2026-07-20 05:38:20 -07:00
Teknium a124d16764
perf: cut first-turn time-to-first-token by ~80% (all platforms) (#59332)
Four independent pre-request stalls sat on the critical path between
prompt submission and the first streamed token, measured with cProfile
against a live process:

1. Discord capability detection (~2.0s, worst 5s): get_tool_definitions
   -> _get_dynamic_schema made a BLOCKING https call to discord.com
   inside AIAgent.__init__ for any user with DISCORD_BOT_TOKEN set, on
   every platform, every cold process. Now non-blocking: memory cache ->
   24h disk cache -> permissive default + one background detection that
   seeds the disk cache for the next process. The permissive default is
   pinned per-process so tool schemas never flip mid-conversation
   (prompt-cache safety); it mirrors the existing detection-failure
   fallback (all actions exposed, 403s enriched at call time).

2. Ollama /api/show probe (~0.3s): get_model_context_length step 5e
   POSTed to <base_url>/api/show for KNOWN providers (openrouter etc.),
   got a 404, and never cached the miss - so every fresh process paid a
   full HTTP round-trip. Known non-Ollama providers now skip the probe;
   local/custom/unknown endpoints keep the exact previous behavior.

3. env_probe subprocess sweep (~0.5s): the Python-toolchain probe ran
   4-8 subprocess calls inside the FIRST system prompt build. Now warmed
   off-thread during agent init; the prompt build hits the cache (same
   lock, so a mid-flight warm just joins instead of recomputing).

4. tools.mcp_tool import (~0.4s): the between-turns MCP refresh in
   build_turn_context imported the whole mcp package even with zero MCP
   servers configured. MCP tools can only exist if tools.mcp_tool was
   already imported (discovery/reload paths), so gate the import on
   sys.modules membership - no behavior change for MCP users.

CLI additionally pre-imports run_agent + openai off-thread during the
idle banner window (same pattern as the /model picker prewarm), hiding
the remaining ~1.5s of module imports while the user types. Fixes 1-4
apply to every interaction layer (CLI, gateway, TUI, desktop, cron).

Measured cold first turn (submit -> request dispatched, openrouter,
discord token set): 4.3s before -> 0.9s after CLI prewarm (~80%); the
agent-side non-import cost drops 2.9s -> 0.36s (init) + 0.27s (turn
prologue).
2026-07-05 21:37:33 -07:00
m4dni5 d1f23bb2d5 fix: prevent TUI gateway stdin EOF crash across all TUI-context subprocess calls
When Hermes runs in TUI mode, the gateway child process communicates with
the Node.js parent over a JSON-RPC protocol on stdin. Subprocess calls that
inherit this stdin fd can trigger a race condition where the child's stdin
read returns EOF, causing the gateway to exit cleanly (exit code 0) mid-tool-
execution.

This is the same root cause as issue #14036 (byterover plugin) and PR #39257
(SSH environment backend). This commit applies the fix — stdin=subprocess.DEVNULL
— to all 85 subprocess.run() and subprocess.Popen() calls that execute inside
the TUI gateway child process.

Scope: TUI-context code only (agent/, tools/, plugins/, tui_gateway/server.py).
CLI code (cli.py, hermes_cli/), tests, scripts, and gateway process management
are excluded — they don't run inside the TUI child and inherit the terminal's
stdin, not the JSON-RPC pipe.

85 call sites across 28 files. All files pass syntax check.
2026-06-08 22:46:57 -07:00
Teknium a4d8f0f62a
feat(prompt): universal task-completion guidance + local Python toolchain probe (#34340)
* fix(codex): surface error code in Responses 'failed' status errors

When a Codex Responses turn ends with status=failed, the response carries
the failure details under `response.error` as
`{code, message, param, ...}`. The previous extractor pulled only
`message`, so users seeing a rate-limit failure got a bare "Slow down"
string indistinguishable from a generic stream truncation; an
internal_error with empty message degraded to a dict dump
("{'code': 'internal_error', 'message': ''}").

Extract a `_format_responses_error()` helper that:
- prefixes `code` when both code and message are present
  (e.g. 'rate_limit_exceeded: Slow down')
- falls back to the bare `code` when message is empty
- accepts both dict and attribute-style payloads (SDK and JSON-RPC paths)
- preserves the prior status-only fallback when no error payload exists

Apply the same helper at the sibling site in
`codex_app_server_session.run_turn()` so codex-CLI subprocess turn
failures get the same treatment.

Tests:
- 8 new unit tests for `_format_responses_error` covering both shapes,
  empty/missing fields, non-string fields, and the status-only fallback.
- 2 regression tests on `_normalize_codex_response` for failed status
  with and without a code, asserting the exact RuntimeError message.
- All 3603 tests in tests/agent/ pass.

Adapted from anomalyco/opencode#28757.

* feat(prompt): universal task-completion guidance + local Python toolchain probe

Two cross-model failure modes get a single-line answer in the cached
system prompt. Both gated by config (default on), both add zero overhead
when not needed, both verified via real AIAgent prompt builds.

## What changed

`TASK_COMPLETION_GUIDANCE` — short prompt block applied to ALL models.
Targets two failure modes observed on a real Sarasota real-estate build
task: (1) Opus stopped after writing an 85-byte stub and gave a prose
response with finish_reason=stop on call #3 of 90; (2) DeepSeek pushed
through a PEP-668 wall, then returned fabricated listings instead of
admitting the blocker. Both behaviors are model-family-agnostic, so the
guidance lives outside the existing tool_use_enforcement gate (~192
tokens, paid once per session via prefix cache).

`tools/env_probe.py` — local Python toolchain probe. Detects
python3/pip/uv/PEP-668 state and emits ONE short line in the system
prompt when something is non-default. Emits NOTHING when the env is
clean (zero token cost for normal users). Skipped entirely for remote
terminal backends (docker/modal/ssh) — they have their own probe.

Example output on a broken environment (the actual case):

    Python toolchain: python3=3.11.15 (no pip module),
    python=missing (use python3), pip→python3.12 (mismatch),
    PEP 668=yes (use venv or uv).

## Config

Both flags live under `agent.` in config.yaml, default True:

    agent:
      task_completion_guidance: true   # universal "finish the job" block
      environment_probe: true          # local Python toolchain hints

Neither addition required a `_config_version` bump — deep-merge fills
defaults in for existing user configs.

## Validation

| Test surface | Result |
|---|---|
| tests/tools/test_env_probe.py | 10/10 pass (probe unit) |
| tests/run_agent/test_run_agent.py — new classes | 8/8 pass (integration) |
| TestToolUseEnforcementConfig | 17/17 pass (no regression) |
| TestBuildSystemPrompt | 9/9 pass (no regression) |
| TestInvalidateSystemPrompt | 2/2 pass (no regression) |
| tests/agent/test_prompt_builder.py | 124/124 pass (no regression) |
| tests/hermes_cli/ | 5662/5662 pass (config defaults) |
| E2E AIAgent build (broken env) | Both blocks present, 2,178 chars |
| E2E AIAgent build (clean env) | 771-char net overhead, env probe silent |
2026-05-28 22:26:09 -07:00