Second, deeper pass over tools/gateway/hermes_cli plus first pass over
the trees wave 1 missed (acp, acp_adapter, skills, computer_use, docker,
dashboard, conformance, monitoring, secret_sources, hermes_state,
providers). Same rubric as wave 1 (AGENTS.md test policy); security,
alternation/caching invariants, issue-number regressions, and E2E kept.
Real test-quality fixes found and rooted out along the way:
- tests/tools/test_command_guards.py made real auxiliary-LLM HTTPS calls
(DEFAULT_CONFIG smart-approval leaked in) — pinned approval
mode=manual via autouse fixture: 17.4s → 0.4s.
- test_model_switch_custom_providers.py / test_user_providers_model_switch.py
silently probed live provider catalogs (~2s/test) — stubbed
cached_provider_model_ids/provider_model_ids/fetch_api_models.
- test_telegram_noise_filter.py: 15-platform copy-paste matrix over
shared gateway.run logic → 3 representative platforms (55s → 3.9s).
- test_gateway_shutdown.py: stop()'s 5s interrupt-deadline loop spun on
MagicMock agents — interrupt.side_effect now clears _running_agents
(22s → 1.0s).
- test_gateway_inactivity_timeout.py poll-harness timings shrunk 3-5x
(24s → 1.1s); test_mcp_stability.py backoff/SIGTERM-grace sleeps
patched (15.4s → 2.5s); test_async_delegation.py negative-drain wait
5s → 0.5s.
- test_telegram_init_deadline.py: loop-block margin restored to 1.0s
with rationale comment — the watchdog-dump assertion needs the loop
blocked well past deadline+grace under parallel load (flaked once in
the 40-worker verification run at a 0.2s margin).
Verification: full hermetic suite via scripts/run_tests.sh —
2,438 files, 21,718 tests passed, 0 failed, 293.9s wall.
Suite totals vs original baseline: 46,820 → 19,757 test functions
(−57.8%), wall 583.5s → 293.9s (−50%), subprocess CPU 13,564s → 11,623s.
Remove unused imports (F401) and duplicate/shadowed import
redefinitions (F811) across the codebase using ruff's safe
autofixes. No behavioral changes -- imports only.
- ~1400 safe autofixes applied across 644 files (net -1072 lines)
- __init__.py re-exports preserved (excluded from F401 removal so
public re-export surfaces stay intact)
- Re-exports that are imported or monkeypatched by tests but look
unused in their defining module are kept with explicit # noqa:
F401 (gateway/run.py load_dotenv; run_agent re-exports from
agent.message_sanitization, agent.context_compressor,
agent.retry_utils, agent.prompt_builder, agent.process_bootstrap,
agent.codex_responses_adapter)
- Unsafe F841 (unused-variable) fixes deliberately skipped -- those
can change behavior when the RHS has side effects
- ruff lints remain disabled in pyproject.toml (only PLW1514 is
selected); this is a one-time cleanup, not a config change
Verification:
- python -m compileall: clean
- pytest --collect-only: all 27161 tests collect (zero import errors)
- core entry points import clean (run_agent, model_tools, cli,
toolsets, hermes_state, batch_runner, gateway)
- static scan: every name any test imports directly from an edited
module still resolves
CPython's logging module is not reentrant-safe. `Logger.isEnabledFor`
caches level results in `Logger._cache`; under shutdown races the cache
can be cleared (`Logger._clear_cache`, triggered by logging config changes
from another thread) or mid-mutation when a signal fires, raising
`KeyError: <level_int>` (e.g. `KeyError: 10` for DEBUG) inside the signal
handler.
When that happens, the KeyError escapes before the `raise KeyboardInterrupt()`
on the next line can fire, which bypasses prompt_toolkit's normal interrupt
unwind and surfaces as the EIO cascade originally reported in #13710.
Issue #13710 shipped two defenses (asyncio exception handler + outer
`except (KeyError, OSError)` with EIO suppression) that cover the EIO
unwind path. This patch closes the remaining escape hatch: the
`logger.debug` call at the top of `_signal_handler` itself. Wrap it in a
bare `try/except Exception: pass` so logging can never raise through a
signal handler.
Observed in the wild: debug report on 0.12.0 (commit 8163d371) shows the
exact stack — KeyError: 10 at logging/__init__.py:1742 inside the
signal handler's `logger.debug`, followed by the EIO cascade from
prompt_toolkit's emergency flush.
Tests: adds `TestSignalHandlerLoggingRace` to
`tests/hermes_cli/test_suppress_eio_on_interrupt.py` with 6 new cases:
- normal path still raises KeyboardInterrupt
- KeyError(10) from logger.debug does not escape
- any Exception from logger.debug is swallowed
- agent.interrupt still fires when logger.debug raises
- agent.interrupt raising also does not escape
- BaseException (SystemExit) is NOT swallowed — guard uses `except Exception`
deliberately so real shutdown signals still propagate
Closes#13710 regression.
When the user interrupts a long-running task, prompt_toolkit tries to
flush stdout during emergency shutdown. If stdout is in a broken state
(redirected to /dev/null, pipe closed, terminal gone), the flush raises
`OSError: [Errno 5] Input/output error` which propagates unhandled and
crashes the CLI.
Two defense layers:
1. `_suppress_closed_loop_errors`: add `OSError` with `errno.EIO` to
the asyncio exception handler, matching the existing pattern for
`RuntimeError("Event loop is closed")` and `KeyError("is not
registered")`.
2. Outer `except (KeyError, OSError)` block: add `errno.EIO` check
before the existing string-match guards, silently suppressing the
error instead of printing a misleading stdin-related message.
Fixes#13710.