hermes-agent/hermes_cli/_scan_venv_blockers.py

169 lines
6.0 KiB
Python

"""``hermes_cli/_scan_venv_blockers.py`` — Standalone venv-process scan for JSON consumption.
Invoked by the Desktop Electron app::
venv\\Scripts\\python.exe -m hermes_cli._scan_venv_blockers
Exits 0 for valid clear or blocked results. Non-zero exit signals probe
failure (the detector itself crashed, psutil unavailable, etc.). Exactly
one JSON document on stdout; diagnostics on stderr only.
"""
from __future__ import annotations
import json
import sys
from typing import NoReturn
# Long CLI flags whose argument value must be redacted from the cmdline.
_SENSITIVE_LONG_FLAGS: list[str] = [
"--token",
"--api-key",
"--password",
"--secret",
"--authorization",
"--access-key",
"--private-key",
"--session-key",
]
def _probe_fail_json() -> str:
"""Return the standard probe-failure JSON document."""
return json.dumps({"ok": False, "blocked": False, "processes": []})
def _emit_probe_fail(diagnostic: str) -> NoReturn:
"""Print one JSON to stdout, diagnostic to stderr, exit non-zero."""
print(_probe_fail_json())
print(diagnostic, file=sys.stderr)
sys.exit(1)
def _find_flag(text: str, flag: str) -> int:
"""Return the index of *flag* when it starts the string or follows a space.
Returns -1 when not found. This avoids matching ``--token`` inside an
embedded token or path like ``/some--token-thing``.
"""
low = text.lower()
fl = flag.lower()
pos = 0
while True:
idx = low.find(fl, pos)
if idx == -1:
return -1
if idx == 0 or text[idx - 1] == " ":
return idx
pos = idx + 1
def _redact_sensitive_cmdline(cmdline: str) -> str:
"""Apply generic secret redaction then long-flag redaction.
If the generic redactor itself fails, return ``"<redacted>"`` — the PID
and process name still provide actionable diagnostics.
"""
# Generic pass: the project's shared secret redactor.
try:
from agent.redact import redact_sensitive_text # noqa: PLC0415
cmdline = redact_sensitive_text(cmdline, force=True)
except Exception:
return "<redacted>"
# Conservative long-flag pass: preserve the flag name, replace the value
# and everything after it with ``<redacted>``. Short flags (-t, -k, -p)
# are intentionally not redacted — they are ambiguous and may be useful
# diagnostics (toolset, port, profile).
earliest = len(cmdline)
for flag in _SENSITIVE_LONG_FLAGS:
# --flag=value → preserve "--flag="
idx = _find_flag(cmdline, flag + "=")
if idx != -1 and idx + len(flag) + 1 < earliest:
earliest = idx + len(flag) + 1
# --flag value → preserve "--flag "
idx = _find_flag(cmdline, flag + " ")
if idx != -1 and idx + len(flag) + 1 < earliest:
earliest = idx + len(flag) + 1
if earliest < len(cmdline):
return cmdline[:earliest] + "<redacted>"
return cmdline
def _is_pausable_gateway(cmdline: str) -> bool:
"""Return True when *cmdline* is a gateway process the updater can pause.
A running gateway shows up in the venv-holder scan as one or both halves
of its launcher/worker chain (``venv\\Scripts\\python.exe -m
hermes_cli.main gateway run`` and the uv-side interpreter re-running the
same argv). Reporting those as blockers dead-ends the Desktop update:
the preflight aborts with ``venv-blocked`` *before* spawning
``hermes-setup``, so the CLI updater's own
``_pause_windows_gateways_for_update()`` — which exists precisely to
stop these processes (and is always active: ``hermes-setup`` invokes
``hermes update --yes --gateway``) — never gets the chance to run.
Only gateway invocations are exempted. Anything else running from the
venv (an operator's REPL, a stray script, a ``serve`` backend that
survived the desktop's own teardown) has no pause machinery downstream
and must keep blocking the handoff.
Delegates to ``gateway.status.looks_like_gateway_command_line`` — the
canonical ``gateway run`` matcher (profile-selector aware, shlex
tokenization, ``run``-only) — so this exemption, the pause discovery,
and the updater's guard fallback all share one parser. A hand-rolled
token scan here regressed ``--profile gateway gateway run``: the profile
*value* shadowed the subcommand token. An import failure counts as
not-pausable — the scan then reports the process as a blocker, which is
exactly the pre-exemption behavior.
"""
try:
from gateway.status import looks_like_gateway_command_line # noqa: PLC0415
except Exception:
return False
return looks_like_gateway_command_line(cmdline)
def main() -> None:
"""Entry point. Prints one JSON doc to stdout. Exits 0 for valid scan."""
try:
import psutil # noqa: PLC0415, F401
except Exception as exc:
_emit_probe_fail(f"psutil is not available: {exc}")
try:
from hermes_cli.main import _detect_venv_python_processes # noqa: PLC0415
matches = _detect_venv_python_processes()
except Exception as exc:
_emit_probe_fail(f"scan aborted: {exc}")
processes = [
{
"pid": pid,
"name": name,
# Truncate for display AFTER the gateway exemption has seen the
# full cmdline (long managed-runtime interpreter paths would
# otherwise swallow the `gateway run` argv).
"cmdline": _redact_sensitive_cmdline(cmdline)[:120],
}
for pid, name, cmdline in matches
if not _is_pausable_gateway(cmdline)
]
exempted = sum(1 for _pid, _name, cmdline in matches if _is_pausable_gateway(cmdline))
data = {
"ok": True,
"blocked": bool(processes),
"processes": processes,
# Diagnostic only: gateway processes present but not counted as
# blockers because the downstream updater pauses them itself.
"pausable_gateways": exempted,
}
print(json.dumps(data))
sys.exit(0)
if __name__ == "__main__":
main()